Chemical
Chemical and Fine Chemical Facilities
OverviewChemical and Fine Chemical Facilities
Overview
- Chemical and fine-chemical plants
- API production facilities
- Hazardous-material storage and handling
- Explosion-proof areas
- Laboratories and research facilities
Chemical and fine-chemical plants and active pharmaceutical ingredient (API) facilities need clean environments for reaction and synthesis processes, together with safe hazardous-material storage, handling and process exhaust. SAMYOUNG ENG has delivered GMP cleanrooms and HVAC for production buildings, hazardous-material stores, exhaust and explosion-proof systems, and laboratories for chemical and fine-chemical clients such as Yuhan Chemical and Hanmi Fine Chemical.
Scope of WorkWhat we deliver
Scope of work
01GMP works for chemical and API production
GMP cleanrooms, HVAC and refrigeration for reaction and API synthesis buildings, as new builds, extensions or remodels.
02Hazardous-material storage and handling
Stores with fire- and explosion-resistant structures, separate compartments per material, forced ventilation and leak detection, explosion-proof electrics and lighting, and low-temperature storage.
03Exhaust and explosion-proof systems
Process exhaust duct systems, explosion-proof dampers and ducts, and exhaust-environment improvements.
04Laboratories and research facilities
HVAC and constant temperature/humidity for QC and physicochemical laboratories, and laboratory extensions.
Key ProjectsSelected work for chemical clients
Key projects
New production building2022
HVAC and refrigeration for the new HB building, Hwaseong plant
Yuhan Chemical
API2023
Unit cooler and condensing unit for the cephalosporin API warehouse (RF-704)
Hanmi Fine Chemical
API synthesis2021
GMP remodeling of the API synthesis building, Osong plant
INIST ST
Hazardous-material storage2021
GMP systems for a low-temperature indoor hazardous-material store
Yuhan Chemical
Explosion-proof exhaust2009
Explosion-proof dampers, ducts and pump-room panels for the cGMP plant
Hanmi Fine Chemical
Laboratory2024
Condensing-unit HVAC for the physicochemical laboratory
Hanmi Fine Chemical
Types of work deliveredTypes of work delivered
Types of work delivered
Work actually delivered for chemical and fine-chemical clients and for hazardous-material and API synthesis facilities, grouped by type.
View as table
| Type | Work delivered (client, year) |
|---|---|
| Production GMP cleanrooms and HVAC | GMP HVAC for HB building bay 2, Hwaseong (Yuhan Chemical, 2024) GMP HVAC remodeling of production building C (Hanmi Fine Chemical, 2022) Cleanroom remodeling of the 3rd-floor reaction room, building F, Ansan (Yuhan Chemical, 2011) |
| API and API synthesis | GMP remodeling of the API synthesis building, Osong (INIST ST, 2021) Unit cooler and condensing unit for the cephalosporin API warehouse (Hanmi Fine Chemical, 2023) |
| Hazardous-material stores | GMP systems for a low-temperature indoor hazardous-material store (Yuhan Chemical, 2021) Refrigeration for the low-temperature hazardous-material store, Ansan (Yuhan Chemical, 2021) Hazardous-material tank-store extension (Medica Korea, 2022) |
| Exhaust and explosion protection | Explosion-proof dampers, ducts and pump-room panels for the cGMP plant (Hanmi Fine Chemical, 2009) Exhaust duct system for the distillation building, Ansan (Yuhan Chemical, 2007) |
| Laboratories | Condensing-unit HVAC for the physicochemical laboratory (Hanmi Fine Chemical, 2024) QC laboratory extension, Hwaseong (Yuhan Chemical, 2023) |
Material and hazardous-material storesMaterial and hazardous-material stores
Material and hazardous-material stores
Material stores prevent loss, damage and contamination while organising inventory. Hazardous-material stores safely hold flammable, explosive and other hazardous substances to legal standards, preventing accidents and protecting workers and the environment.
Material and hazardous-material stores need suitable structures, ventilation, security and safety systems to ensure both productivity and safety.
Material and hazardous-material storage features
Structural works
Material store features- General steel/reinforced concrete
- Load-bearing/seismic design
- Floor flatness
Hazardous-material store features- Fire/explosion-resistant structures
- Separate hazardous-material compartments
- Oil-retaining/explosion-resistant floor design
Interiors/finishes
Material store features- Dust/moisture-resistant finishes
- Separate materials by compartment and FIFO routes
- Easy-clean finishes
Hazardous-material store features- Fire/chemical-resistant finishes
- Separate compartments for each hazardous material
- Leak-prevention finishes
Building services
Material store features- Ventilation and temperature/humidity control
- Lighting, electricity, CCTV and access control
Hazardous-material store features- Forced ventilation and leak detection
- Explosion-proof electrical systems/lighting
- Alarms and fire suppression
Security/safety
Material store features- Access control
- CCTV and security equipment
Hazardous-material store features- Access control and hazardous-material warning signs
- Emergency escape routes and alarms
- Fire suppression and disaster prevention
Other
Material store features- Inventory management (FIFO, barcodes)
- Racks, pallets and other storage equipment
Hazardous-material store features- Compliant hazardous-material containers
- Legal separation distances and capacities
- Applicable regulations and certifications
View as table
| Category | Material store features | Hazardous-material store features |
|---|---|---|
| Structural works | General steel/reinforced concrete Load-bearing/seismic design Floor flatness | Fire/explosion-resistant structures Separate hazardous-material compartments Oil-retaining/explosion-resistant floor design |
| Interiors/finishes | Dust/moisture-resistant finishes Separate materials by compartment and FIFO routes Easy-clean finishes | Fire/chemical-resistant finishes Separate compartments for each hazardous material Leak-prevention finishes |
| Building services | Ventilation and temperature/humidity control Lighting, electricity, CCTV and access control | Forced ventilation and leak detection Explosion-proof electrical systems/lighting Alarms and fire suppression |
| Security/safety | Access control CCTV and security equipment | Access control and hazardous-material warning signs Emergency escape routes and alarms Fire suppression and disaster prevention |
| Other | Inventory management (FIFO, barcodes) Racks, pallets and other storage equipment | Compliant hazardous-material containers Legal separation distances and capacities Applicable regulations and certifications |
Exhaust gas treatment (scrubbers)Exhaust gas treatment (scrubbers)
Exhaust gas treatment (scrubbers)
As a rule, facilities that install emission sources must install air-pollution prevention facilities so that emitted pollutants stay within the emission limits (Clean Air Conservation Act, Article 26). [1]
Annex 4 of the Act's Enforcement Rule lists 16 types of prevention facility, including wet scrubbing dust collectors, absorption facilities and adsorption facilities; a prevention facility also includes the hoods and ducts that capture pollutants and its attached equipment such as fans and pumps. [1]
The Ministry of Employment and Labor's self-inspection checklist for the chemical industry classes scrubbers with adsorption towers and combustion/incineration units as environmental treatment equipment, and checks that the scrubber circulation pump works and that the pump and circulation piping are free of damage and leaks. [2]
SAMYOUNG ENG's related work is on the exhaust side: exhaust duct systems, explosion-proof dampers and ducts, laboratory exhaust-duct extensions with arm hoods, and activated-carbon installation in a dust collector (2025 company profile track record).
Sources
- Ministry of Government Legislation, Easy Law: Air pollution prevention facilities (Clean Air Conservation Act Art. 26; Enforcement Rule Art. 6 and Annex 4)
- Ministry of Employment and Labor, Safety and health self-inspection checklist for small and medium chemical businesses (2022), 2-2-10 Environmental treatment equipment
Related regulationsRelated regulations
Related regulations
Depending on the substances and quantities handled, the facility standards of the following laws apply to the design and construction of chemical and fine-chemical facilities.
- Hazardous Materials Safety Management Act: location, structure and equipment standards for hazardous-material manufacturing, storage and handling facilities
- Chemicals Control Act: installation and management standards for hazardous-chemical handling facilities
- Occupational Safety and Health Act: workplace safety standards such as local exhaust ventilation and explosion-hazard (explosion-proof) areas
- Pharmaceutical Affairs Act (Rules on the Safety of Pharmaceuticals): GMP standards for API manufacturing facilities
Other business areas
Contact Us
Your next project starts here.
Talk to us about the right engineering approach for your facility, scale and schedule.